Electrochemical corrosion assessment of RaCe and Mtwo rotary nickle-titanium instruments after clinical use and sterilization

2010

Aim: The aim of the present study was to electrochemically evaluate corrosion resistance of RaCe and Mtwo files after repeated sterilization and preparation procedures. Study Design: A total of 450 rotary files were used. In the working groups, 72 files from each file type were distributed into 4 groups. RaCe and Mtwo files were used to prepare one root canal of the mesial root of extracted human mandibular first molars. The procedure was repeated to prepare 2 to 8 canals. The following irrigation solutions were used: group 1, RaCe files with 2.5% NaOCl; group 2, RaCe files with normal saline; group 3, Mtwo files with 2.5% NaOCl; and group 4, Mtwo files with normal saline in the manner desc…

Dental InstrumentsRoot canalDentistryMesial rootNickelClinical and Experimental DentistryMaterials TestingmedicineIrrigation SolutionsHumansStatistical analysisGeneral DentistryPreparation proceduresTitaniumbusiness.industrySterilizationElectrochemical TechniquesEquipment DesignSterilization (microbiology):CIENCIAS MÉDICAS [UNESCO]Electrochemical corrosionCorrosionmedicine.anatomical_structureOtorhinolaryngologyUNESCO::CIENCIAS MÉDICASResearch-ArticleSurgerybusiness
researchProduct

Effect of three different irrigation solutions applied by passive ultrasonic irrigation

2015

Objectives This study evaluated the maximum depth and percentage of irrigant penetration into dentinal tubules by passive ultrasonic irrigation (PUI). Materials and Methods Thirty extracted human teeth were instrumented and divided into three groups. According to final irrigation regimen, 5.25% sodium hypochlorite (Group A, NaOCl), 2% chlorhexidine (Group B, CHX) and saline solution (Group C, control group) were applied with Irrisafe 20 tips (Acteon) and PUI. Irrigant was mixed with 0.1% rhodamine B. Sections at 2 mm, 5 mm, and 8 mm from the apex were examined with confocal laser scanning microscopy (CLSM). The percentage and maximum depth of irrigant penetration were measured. Kruskal-Wall…

Ultrasonic irrigationMaterials scienceDentinal penetrationConfocal laser scanning microscopeConfocal laser scanning microscopeChlorhexidineNanotechnologyGeneral MedicinePenetration (firestop)lcsh:RK1-715Passive ultrasonic irrigationSodium hypochloritestomatognathic diseaseschemistry.chemical_compoundDentinal Tubulestomatognathic systemchemistryMaximum depthlcsh:DentistrySodium hypochloriteIrrigation SolutionsResearch ArticleBiomedical engineeringRestorative Dentistry & Endodontics
researchProduct